during charging Active current 25.0->0.0 due to current limit: EMS-socket when the intregation is enabled . when i disable and resart the charger its back ok ( full charging the car ) . What i also did is disable / enable loadbalance function to start charging .
When the integration makes connection with the charger it goes into safe mode when you charge a car:
2014-01-01T00:04:35.128Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:04:35.136Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:04:50.468Z:USER:taskMaster.c:5760:Socket #1: L1N=230.4V L2N=232.1V L3N=228.8V L1L2=n/a L2L3=n/a L3L1=n/a
2014-01-01T00:04:50.480Z:USER:taskMaster.c:5796:Socket #1: I1=16.1A I2=16.2A I3=16.2A P=11.2kW Idc=0.7mA
2014-01-01T00:05:20.464Z:USER:taskMaster.c:5760:Socket #1: L1N=230.6V L2N=232.2V L3N=228.8V L1L2=n/a L2L3=n/a L3L1=n/a
2014-01-01T00:05:20.476Z:USER:taskMaster.c:5796:Socket #1: I1=16.1A I2=16.3A I3=16.2A P=11.2kW Idc=0.7mA== here stil ok
2014-01-01T00:05:20.488Z:INFO:taskMaster.c:5702:Stop logging meter values @30s.
2014-01-01T00:09:29.597Z:INFO:taskMain.c:4928:Socket #1: Active current 25.0->0.0 due to current limit: EMS-socket
2014-01-01T00:09:29.609Z:WARNING:taskMain.c:4639:Socket #1: >150% overcurrent triggered: 16.1 > 6.0
2014-01-01T00:09:29.621Z:WARNING:taskMain.c:3764:Socket #1: maximum current(0.00) < minimum current(6.00)
2014-01-01T00:09:29.632Z:INFO:taskMaster.c:3999:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2014-01-01T00:09:29.644Z:INFO:taskMaster.c:4018:Socket #1: state Mode-3: STATE_C1
2014-01-01T00:09:29.652Z:INFO:taskMaster.c:4025:Socket #1: state led : LOADBALANCING_FORCED_OFF
2014-01-01T00:09:29.777Z:INFO:taskMain.c:5278:Socket #1: CPlow 5.71 V
2014-01-01T00:09:29.835Z:INFO:taskMaster.c:5492:Socket #1: CPlow : 5.7 V
2014-01-01T00:09:30.136Z:INFO:taskMaster.c:4011:Socket #1: state power : POWER_MAIN_ON_BYPASS_OFF
2014-01-01T00:09:30.640Z:INFO:taskMain.c:5276:Socket #1: CPhigh 8.66 V
2014-01-01T00:09:30.648Z:INFO:taskMain.c:5278:Socket #1: CPlow 8.66 V
2014-01-01T00:15:04.941Z:SECURITY:functionality.c:1111:Changed '2068_00' from 32.000000 => 30.000000
2014-01-01T00:18:59.550Z:INFO:taskMain.c:4928:Socket #1: Active current 0.0->16.0 due to current limit: Start
2014-01-01T00:18:59.566Z:INFO:taskMaster.c:3999:Socket #1: state main : CHARGING_POWER_OFF
2014-01-01T00:18:59.574Z:INFO:taskMaster.c:4018:Socket #1: state Mode-3: STATE_B2
2014-01-01T00:18:59.582Z:INFO:taskMaster.c:4025:Socket #1: state led : WAIT_FOR_EVCONNECT
2014-01-01T00:19:00.113Z:INFO:taskMaster.c:3999:Socket #1: state main : CHARGING_POWER_ON
2014-01-01T00:19:00.125Z:INFO:taskMaster.c:5714:Start logging meter values @30s.
2014-01-01T00:19:00.132Z:USER:taskMaster.c:5760:Socket #1: L1N=234.9V L2N=234.0V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a 2014-01-01T00:19:00.144Z:USER:taskMaster.c:5796:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA == not ok
Still al lot of :
2014-01-01T00:23:45.554Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:45.562Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:47.691Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:47.699Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:49.816Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:49.824Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:51.921Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:51.929Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:54.027Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:54.039Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:56.140Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:56.152Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:58.257Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:58.269Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:24:00.128Z:USER:taskMaster.c:5760:Socket #1: L1N=230.3V L2N=233.8V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2014-01-01T00:24:00.140Z:USER:taskMaster.c:5796:Socket #1: I1=16.1A I2=16.2A I3=16.2A P=11.2kW Idc=0.7mA
2014-01-01T00:24:00.152Z:INFO:taskMaster.c:5702:Stop logging meter values @30s.
2014-01-01T00:24:00.375Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:24:00.386Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:24:02.492Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:24:02.500Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
The text was updated successfully, but these errors were encountered:
during charging Active current 25.0->0.0 due to current limit: EMS-socket when the intregation is enabled . when i disable and resart the charger its back ok ( full charging the car ) . What i also did is disable / enable loadbalance function to start charging .
When the integration makes connection with the charger it goes into safe mode when you charge a car:
2014-01-01T00:04:35.128Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:04:35.136Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:04:50.468Z:USER:taskMaster.c:5760:Socket #1: L1N=230.4V L2N=232.1V L3N=228.8V L1L2=n/a L2L3=n/a L3L1=n/a
2014-01-01T00:04:50.480Z:USER:taskMaster.c:5796:Socket #1: I1=16.1A I2=16.2A I3=16.2A P=11.2kW Idc=0.7mA
2014-01-01T00:05:20.464Z:USER:taskMaster.c:5760:Socket #1: L1N=230.6V L2N=232.2V L3N=228.8V L1L2=n/a L2L3=n/a L3L1=n/a
2014-01-01T00:05:20.476Z:USER:taskMaster.c:5796:Socket #1: I1=16.1A I2=16.3A I3=16.2A P=11.2kW Idc=0.7mA== here stil ok
2014-01-01T00:05:20.488Z:INFO:taskMaster.c:5702:Stop logging meter values @30s.
2014-01-01T00:09:29.597Z:INFO:taskMain.c:4928:Socket #1: Active current 25.0->0.0 due to current limit: EMS-socket
2014-01-01T00:09:29.609Z:WARNING:taskMain.c:4639:Socket #1: >150% overcurrent triggered: 16.1 > 6.0
2014-01-01T00:09:29.621Z:WARNING:taskMain.c:3764:Socket #1: maximum current(0.00) < minimum current(6.00)
2014-01-01T00:09:29.632Z:INFO:taskMaster.c:3999:Socket #1: state main : CHARGING_POWER_OFF_LOW_MAXCURRENT
2014-01-01T00:09:29.644Z:INFO:taskMaster.c:4018:Socket #1: state Mode-3: STATE_C1
2014-01-01T00:09:29.652Z:INFO:taskMaster.c:4025:Socket #1: state led : LOADBALANCING_FORCED_OFF
2014-01-01T00:09:29.777Z:INFO:taskMain.c:5278:Socket #1: CPlow 5.71 V
2014-01-01T00:09:29.835Z:INFO:taskMaster.c:5492:Socket #1: CPlow : 5.7 V
2014-01-01T00:09:30.136Z:INFO:taskMaster.c:4011:Socket #1: state power : POWER_MAIN_ON_BYPASS_OFF
2014-01-01T00:09:30.640Z:INFO:taskMain.c:5276:Socket #1: CPhigh 8.66 V
2014-01-01T00:09:30.648Z:INFO:taskMain.c:5278:Socket #1: CPlow 8.66 V
2014-01-01T00:15:04.941Z:SECURITY:functionality.c:1111:Changed '2068_00' from 32.000000 => 30.000000
2014-01-01T00:18:59.550Z:INFO:taskMain.c:4928:Socket #1: Active current 0.0->16.0 due to current limit: Start
2014-01-01T00:18:59.566Z:INFO:taskMaster.c:3999:Socket #1: state main : CHARGING_POWER_OFF
2014-01-01T00:18:59.574Z:INFO:taskMaster.c:4018:Socket #1: state Mode-3: STATE_B2
2014-01-01T00:18:59.582Z:INFO:taskMaster.c:4025:Socket #1: state led : WAIT_FOR_EVCONNECT
2014-01-01T00:19:00.113Z:INFO:taskMaster.c:3999:Socket #1: state main : CHARGING_POWER_ON
2014-01-01T00:19:00.125Z:INFO:taskMaster.c:5714:Start logging meter values @30s.
2014-01-01T00:19:00.132Z:USER:taskMaster.c:5760:Socket #1: L1N=234.9V L2N=234.0V L3N=231.9V L1L2=n/a L2L3=n/a L3L1=n/a
2014-01-01T00:19:00.144Z:USER:taskMaster.c:5796:Socket #1: I1=0.0A I2=0.0A I3=0.0A P=0.0kW Idc=0.7mA == not ok
Still al lot of :
2014-01-01T00:23:45.554Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:45.562Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:47.691Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:47.699Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:49.816Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:49.824Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:51.921Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:51.929Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:54.027Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:54.039Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:56.140Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:56.152Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:23:58.257Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:23:58.269Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:24:00.128Z:USER:taskMaster.c:5760:Socket #1: L1N=230.3V L2N=233.8V L3N=231.1V L1L2=n/a L2L3=n/a L3L1=n/a
2014-01-01T00:24:00.140Z:USER:taskMaster.c:5796:Socket #1: I1=16.1A I2=16.2A I3=16.2A P=11.2kW Idc=0.7mA
2014-01-01T00:24:00.152Z:INFO:taskMaster.c:5702:Stop logging meter values @30s.
2014-01-01T00:24:00.375Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:24:00.386Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
2014-01-01T00:24:02.492Z:WARNING:_functionality.c:418:Failed to parse property '2191_2'
2014-01-01T00:24:02.500Z:WARNING:_functionality.c:418:Failed to parse property '2191_3'
The text was updated successfully, but these errors were encountered: