** Drc report for Z:\Electronics\KiCAD\Projects\ElectricalVehicleBatCharger\ElectricalVehicleBatCharger.kicad_pcb **
** Created on **
** Found 22 DRC errors **
ErrType(19): Pad near pad
@ (232.766 mm,143.595 mm): Pad 1 on F.Cu, Non-copper of D19
@ (232.766 mm,145.693 mm): Pad 2 on F.Cu, Non-copper of D19
ErrType(19): Pad near pad
@ (232.766 mm,148.660 mm): Pad 2 on F.Cu, Non-copper of D18
@ (232.766 mm,150.758 mm): Pad 1 on F.Cu, Non-copper of D18
ErrType(19): Pad near pad
@ (234.474 mm,109.107 mm): Pad 2 on F.Cu, B.Cu, Internal, Non-copper of C95
@ (234.474 mm,111.607 mm): Pad 1 on F.Cu, B.Cu, Internal, Non-copper of C95
ErrType(19): Pad near pad
@ (234.474 mm,117.807 mm): Pad 2 on F.Cu, B.Cu, Internal, Non-copper of C96
@ (234.474 mm,120.307 mm): Pad 1 on F.Cu, B.Cu, Internal, Non-copper of C96
ErrType(19): Pad near pad
@ (234.474 mm,126.107 mm): Pad 2 on F.Cu, B.Cu, Internal, Non-copper of C70
@ (234.474 mm,128.607 mm): Pad 1 on F.Cu, B.Cu, Internal, Non-copper of C70
ErrType(19): Pad near pad
@ (234.574 mm,134.207 mm): Pad 2 on F.Cu, B.Cu, Internal, Non-copper of C97
@ (234.574 mm,136.707 mm): Pad 1 on F.Cu, B.Cu, Internal, Non-copper of C97
ErrType(19): Pad near pad
@ (242.074 mm,109.107 mm): Pad 2 on F.Cu, B.Cu, Internal, Non-copper of C101
@ (242.074 mm,111.607 mm): Pad 1 on F.Cu, B.Cu, Internal, Non-copper of C101
ErrType(19): Pad near pad
@ (242.074 mm,117.807 mm): Pad 2 on F.Cu, B.Cu, Internal, Non-copper of C100
@ (242.074 mm,120.307 mm): Pad 1 on F.Cu, B.Cu, Internal, Non-copper of C100
ErrType(19): Pad near pad
@ (242.074 mm,126.207 mm): Pad 2 on F.Cu, B.Cu, Internal, Non-copper of C98
@ (242.074 mm,128.707 mm): Pad 1 on F.Cu, B.Cu, Internal, Non-copper of C98
ErrType(19): Pad near pad
@ (242.074 mm,134.207 mm): Pad 2 on F.Cu, B.Cu, Internal, Non-copper of C99
@ (242.074 mm,136.707 mm): Pad 1 on F.Cu, B.Cu, Internal, Non-copper of C99
ErrType(19): Pad near pad
@ (242.918 mm,146.143 mm): Pad 1 on F.Cu, Non-copper of R101
@ (245.418 mm,146.143 mm): Pad 2 on F.Cu, Non-copper of R102
ErrType(19): Pad near pad
@ (242.918 mm,148.243 mm): Pad 1 on F.Cu, Non-copper of R99
@ (245.418 mm,148.243 mm): Pad 2 on F.Cu, Non-copper of R100
ErrType(19): Pad near pad
@ (251.231 mm,107.484 mm): Pad 2 on F.Cu, Non-copper of U9
@ (252.501 mm,107.484 mm): Pad 3 on F.Cu, Non-copper of U9
ErrType(19): Pad near pad
@ (258.126 mm,79.857 mm): Pad 1 on F.Cu, Non-copper of R38
@ (260.626 mm,79.857 mm): Pad 1 on F.Cu, Non-copper of R43
ErrType(4): Track near pad
@ (239.375 mm,73.824 mm): Track 0.500 mm, net [GNDREF] (23) on layer F.Cu, length: 14.475 mm
@ (241.326 mm,79.749 mm): Pad 1 on F.Cu, Non-copper of R33
ErrType(4): Track near pad
@ (252.501 mm,107.484 mm): Track 0.250 mm, net [GNDREF] (23) on layer F.Cu, length: 1.270 mm
@ (251.231 mm,107.484 mm): Pad 2 on F.Cu, Non-copper of U9
ErrType(16): Two track ends too close
@ (243.826 mm,79.749 mm): Track 0.500 mm, net [/OutputPowerLine] (24) on layer F.Cu, length: 2.500 mm
@ (246.966 mm,83.909 mm): Track 0.500 mm, net [GND] (29) on layer F.Cu, length: 3.677 mm
ErrType(18): Two track ends too close
@ (241.326 mm,79.749 mm): Track 0.500 mm, net [/OutputPowerLine] (24) on layer F.Cu, length: 2.500 mm
@ (246.966 mm,83.909 mm): Track 0.500 mm, net [GND] (29) on layer F.Cu, length: 3.677 mm
ErrType(4): Track near pad
@ (246.966 mm,83.909 mm): Track 0.500 mm, net [GND] (29) on layer F.Cu, length: 3.677 mm
@ (243.826 mm,79.749 mm): Pad 1 on F.Cu, Non-copper of R34
ErrType(4): Track near pad
@ (244.366 mm,81.309 mm): Via 0.600 mm net [GND] (29) on layers F.Cu/B.Cu
@ (243.826 mm,79.749 mm): Pad 1 on F.Cu, Non-copper of R34
ErrType(4): Track near pad
@ (184.066 mm,130.609 mm): Track 5.000 mm, net [/TR_9] (103) on layer F.Cu, length: 7.705 mm
@ (184.066 mm,125.509 mm): Pad 10 on F.Cu, B.Cu, Internal, Non-copper of T1
ErrType(4): Track near pad
@ (190.816 mm,100.009 mm): Track 5.000 mm, net [/TR_15] (104) on layer F.Cu, length: 6.750 mm
@ (184.066 mm,94.909 mm): Pad 16 on F.Cu, B.Cu, Internal, Non-copper of T1
** Found 0 unconnected pads **
** End of Report **