Notifications
You must be signed in to change notification settings - Fork 6
/
Pre_defined_Variables.py
123 lines (118 loc) · 4.48 KB
/
Pre_defined_Variables.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
# -*- coding: utf-8 -*-
"""
Created on Thu Oct 15 12:29:27 2020
@author: osamatarabih
"""
#A Class contains all the pre-defined variables
#I will include different values for variables in this class.
class Pre_defined_Variables:
Schedule = 'LORS20082023'
startyear = 2008
endyear = 2023
startdate_entry = startyear,1,1
begdateCS_entry = startyear,1,1
enddate_entry = endyear,3,31
# enddate_TC = endyear+1,1,1
enddate_TC = endyear,4,1
# Month_N = (endyear-startyear+1)*12
Month_N = (endyear-startyear)*12 + 3
Opt_NewTree = 1 #if New Tree Decision is used enter 1 else enter 0.
Code = 6
Multiplier = 100
TCI = 1
Opt_NetInflow = 2
NetInf_const = 0
startstage = 10.268 #ft
begstageCS = startstage
Opt_LOSAdmd = 1
Mult_LOSA = 100
Opt_LOSAws = 1 #the option for LOSA Daily Supply where 1: Calculated Function of WSM, 2: Set values to zeros.
Opt_DecTree = 1 #if Tree Decision is used enter 1 else enter 0.
Zone_C_MetFcast_Indicator = 1 #0 to use the same tree classifications as SLONINO or 1 to use the same tree classifications as LORS2008 and SFWMM.
WCA3a_REG_Zone = 'ERTP:TopE'
WCA3Aoffset = 0
WCA328min = 7.5
WCA3NWmin = 11
WCA217min = 11.1
Opt_WCAlimitWSA = 2
CSflag = 1
PlsDay_Switch = 0 #0: pulse day counter continues to 10 even if release level increases, 1: pulse day counter is set to zero if release level increases during the 10-day pulse.
MaxQstgTrigger = 20 # the maximum stage trigger for maximum discharge if Trib_cond. = XWet.
Opt_QregMult = 0 #option for using multipliers 0: don't use, 1: apply only during dry season (Nov-May), 2: apply year-round.
AlternateHighQyrs = 0
Option_S80Baseflow = 0 #0: baseflow supplements daily C44RO, 1: baseflow supplements monthly C44RO.
S308BK_Const = 1 #method to calculate S308BK 0: Use Input data or 1: Simulate S308BK.
S308_BK_Thr = 14.5 #threshold for S308 Backflow to occur.
Opt_S308 = 1 #option for using S308 for LOREG and Backflow (1: Y and 0: N).
S308RG_Const = 1 #0: use Input data (overrides Option_RegS77S308) and 1: simulate S308RG.
Option_RegS77S308 = 0 #0: simulate discharge using LOONE, 1: same values as SFWMM LEC2005 Base, 2: Based on SFWMM 46yr run (see SFWMMdata4LOOPS).
S80_Const = 1 #0: to use Input data or 1: to simulate S80.
Opt_Outlet1DSRG = 0 #(Option for Regulatory Releases to CE) = where 0: All releases >ZoneD0 measured at S77 and 1: All Pulse Releases measured at S79.
THC_threshold = 2
LowChance = 50
Opt_LChance_line = 1
Opt_Date_Targ_Stg = 1
OptSalFcast = 3
CE_SalThreshold = 5
Late_Dry_Season_Option = 0
Opt_NoAP_above_BF_SB = 1
Opt_AdapProt = 1
Opt_CEews_LOWSM = 0
Opt_THCbypLateDS = 1
APCB1 = 100
APCB2 = 100
APCB3 = 100
APCB4 = 100
CalEst_ews = 300
Outlet1USEWS_Switch = 1
Outlet1USBK_Switch = 1 #option for S77BK simulation 0: Use input data or 1: Simulate with LOONE.
Outlet1USBK_Threshold = 11.1
Option_S77Baseflow = 0 #0: baseflow supplements daily C43RO, 1: baseflow supplements monthly C43RO.
Outlet1USREG_Switch = 1
Outlet1DS_Switch = 1
MaxCap_RegWCA = 4000
Multiplier_RegWCA = 1
Option_RegWCA = 2
Constant_RegWCA = 400
MaxCap_RegL8C51 = 500
Multiplier_RegL8C51 = 1
Option_RegL8C51 = 2
Constant_RegL8C51 = 200
ET_Switch = 0
Opt_WSA = 0 #Options for Lake O water supply augmentation (WSA) operation (0 = no WSA,1 = use flat trigger stages to activate WSA operation,2 = trigger stages defined using offsets from LOWSM WST line to activate WSA operation)
WSA_THC = 2
WSAtrig1 = 12.5
WSAtrig2 = 11.5
WSAoff1 = 0.5
WSAoff2 = 0
MIAcap1 = 860
MIAcap2 = 1720
NNRcap1 = 900
NNRcap2 = 1800
Option_Stage = 0
#Water demand cutback for each WSM Zone
Z1_cutback = 0.15
Z2_cutback = 0.3
Z3_cutback = 0.45
Z4_cutback = 0.6
##################################################################################
dstar_B = 99
dstar_C = 99
dstar_D3 = 99
dstar_D2 = 99
dstar_D1 = 99
astar_B = 1
astar_C = 1
astar_D3 = 1
astar_D2 = 1
astar_D1 = 1
bstar_S77_B = 1
bstar_S77_C = 1
bstar_S77_D3 = 0.5
bstar_S77_D2 = 0.5
bstar_S77_D1 = 0.5
bstar_S80_B = 1
bstar_S80_C = 1
bstar_S80_D3 = 0.5
bstar_S80_D2 = 0.5
bstar_S80_D1 = 0.5