Implement additional commands #8
Comments
|
|
Hi, any way I can help in order to achieve changing parameters through this implementation? |
Could you use the battery monitor / windows application to capture some commands? There is a debug view to monitor the raw traffic. Could you provide such a capture? |
Changing parameter 50, Charging overcurrent warning to 25A from 35A. If you need something else just ask for it and I will see if I have enough knowledge to deliver. |
Same as before but changing parameter 50, Charging overcurrent warning to 35A from 25A. |
Another one a bit different, desactivating/activating function. |
Cool! I will review the captures as soon as possible and will provide a first draft of the implementation. |
|
Any update on this funcionality? If you need more info to help you ask without a problem. |
https://github.com/Frankkkkk/python-pylontech/blob/master/pylontech/pylontech.py#L176-L207