Notifications
You must be signed in to change notification settings - Fork 0
/
ina226simple.py
47 lines (33 loc) · 921 Bytes
/
ina226simple.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
import time
from machine import Pin, I2C
i2c = None
if not i2c:
sdapin = Pin(18)
sclpin = Pin(19)
i2c = I2C(0, scl=sclpin, sda=sdapin, freq=400000)
print("performing i2scan...")
i2c.scan()
print("performing i2scan... DONE")
ina = None
if not ina:
print("loading INA226 module...")
import ina226
print("loading INA226 module... DONE")
# ina226
ina = ina226.INA226(i2c, 0x40)
# default configuration and calibration value
#ina.set_calibration()
ina.set_calibration_custom(calValue=512, config=0x4cdf) #SHBUSCONT 0x4cdf #SHV_CONT)
def ina226measure():
busvoltage = ina.bus_voltage
shuntvoltage = ina.shunt_voltage
current = ina.current * 1000
power = ina.power
print("Shunt Voltage: %.3f V" % shuntvoltage)
print("Bus Voltage: %.3f V" % busvoltage)
print("Current: %.3f mA" % current)
print("Power: %.3f mW" % power)
print("\n")
for i in range(0, 100):
ina226measure()
time.sleep(1)