Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Calibration Failure, Status =7 #37

Open
hatefdm opened this issue Aug 29, 2019 · 1 comment
Open

Calibration Failure, Status =7 #37

hatefdm opened this issue Aug 29, 2019 · 1 comment

Comments

@hatefdm
Copy link

hatefdm commented Aug 29, 2019

Hi
I'm facing Calibration Failure, Status =7 when running test_loragw_cal with the following result, so the concentrator does not start.

Library version information: Version: 5.0.1;
Radio type: 2
Radio A frequency: 867.500000 MHz
Radio B frequency: 868.500000 MHz
Number of calibration iterations: 5
Calibration command: brd: 0, chip: 1257, dac: 3

WARNING: problem in calibration of radio A for image rejection
WARNING: Calibration not finished
Rx A IQ mismatch: Amp: 0 Phi: 0 Rej: 0 dB Status: 7 | Debug: Rej: 0 dB Lna: 0 BB: 0 Dec: 0
WARNING: problem in calibration of radio A for image rejection
WARNING: Calibration not finished
Rx A IQ mismatch: Amp: 0 Phi: 0 Rej: 0 dB Status: 7 | Debug: Rej: 0 dB Lna: 0 BB: 0 Dec: 0
WARNING: problem in calibration of radio A for image rejection
WARNING: Calibration not finished
Rx A IQ mismatch: Amp: 0 Phi: 0 Rej: 0 dB Status: 7 | Debug: Rej: 0 dB Lna: 0 BB: 0 Dec: 0
WARNING: problem in calibration of radio A for image rejection
WARNING: Calibration not finished
Rx A IQ mismatch: Amp: 0 Phi: 0 Rej: 0 dB Status: 7 | Debug: Rej: 0 dB Lna: 0 BB: 0 Dec: 0
WARNING: problem in calibration of radio A for image rejection
WARNING: Calibration not finished
Rx A IQ mismatch: Amp: 0 Phi: 0 Rej: 0 dB Status: 7 | Debug: Rej: 0 dB Lna: 0 BB: 0 Dec: 0

WARNING: problem in calibration of radio B for image rejection
WARNING: Calibration not finished
Rx B IQ mismatch: Amp: 0 Phi: 0 Rej: 0 dB Status: 7 | Debug: Rej: 0 dB Lna: 0 BB: 0 Dec: 0
WARNING: problem in calibration of radio B for image rejection
WARNING: Calibration not finished
Rx B IQ mismatch: Amp: 0 Phi: 0 Rej: 0 dB Status: 7 | Debug: Rej: 0 dB Lna: 0 BB: 0 Dec: 0
WARNING: problem in calibration of radio B for image rejection
WARNING: Calibration not finished
Rx B IQ mismatch: Amp: 0 Phi: 0 Rej: 0 dB Status: 7 | Debug: Rej: 0 dB Lna: 0 BB: 0 Dec: 0
WARNING: problem in calibration of radio B for image rejection
WARNING: Calibration not finished
Rx B IQ mismatch: Amp: 0 Phi: 0 Rej: 0 dB Status: 7 | Debug: Rej: 0 dB Lna: 0 BB: 0 Dec: 0
WARNING: problem in calibration of radio B for image rejection
WARNING: Calibration not finished
Rx B IQ mismatch: Amp: 0 Phi: 0 Rej: 0 dB Status: 7 | Debug: Rej: 0 dB Lna: 0 BB: 0 Dec: 0

Tx A calibration bypassed

Tx B calibration bypassed

Rx A IQ mismatch calibration statistics on 5 iterations (min, max):
Amp: 0 0 Phi: 0 0 Rej: 0 0 dB (capt.: 0 0 dB)

Rx B IQ mismatch calibration statistics on 5 iterations (min, max):
Amp: 0 0 Phi: 0 0 Rej: 0 0 dB (capt.: 0 0 dB)

End of radio calibration test

I've run util_spi_stress successfully for multiple hours. We have ordered the bare PCB and assembled the board. Any ideas what the problem can be?

@will127534
Copy link
Owner

You might want to double-check the connection between SX1257 and SX1301/1308
Moreover, make sure that the 32Mhz TCXO clock is running, and the power is stable (Note: util_spi_stress doesn't really power-up the power-hungry stuff )