Photoionization: Surface Emission via SEE

  • Particle emission due to secondary electron emission from a surface
  • no deposition, no interpolation
  • comparison of the number of emitted electrons with the analytic solution
  • different MPF and number of MPI ranks are tested to yield the same result
  • Note: Because the volume is exactly 1 cubic metre, the calculated electron density is exactly the number of real electrons in the system