Solax Inverter Automation

Author: Pavel Mikula

A Spring Boot application that runs a Solax X3-Hybrid-G4 for you: it decides when to charge the battery, when to give surplus to the grid, when to hold the battery back as an outage reserve, and when to sell it into the day's price peak. It runs on a Raspberry Pi 4B next to the inverter and serves a web dashboard so you never have to open SolaxCloud to see what it is doing.

Built for one private installation. It is provided "as-is" — read the configuration before you point it at your own inverter.


How it works

Two transports talk to the inverter, and each is used for what it is actually good at:

Modbus TCP SolaX Cloud OpenAPI
Latency instant commands queued, readings minutes old
Cost wears the inverter's flash on every write free
Work mode authoritative read and write can only be inferred from device status
Remote control (selling) not available the only way
Reports battery %, work mode, export limit, PV power everything above plus grid/load power, daily energies, temperatures, SOH

So: persistent work mode changes go over Modbus, selling goes over cloud remote control, and readings take the authoritative values from Modbus and everything else from the cloud. All of that is configurable under solax.control.

Why selling uses remote control rather than a work mode

Putting the inverter into MANUAL / FORCE_DISCHARGE is persistent: if this application crashes, the Pi loses power, or the network drops mid-sale, the inverter keeps emptying the battery into the grid until somebody notices. A remote control session (push_power/positive_or_negative_mode) carries its own duration and nextMotion: exit remote control, so the inverter returns to its configured work mode on its own — no matter what happens on this side. The persistent work mode is therefore only ever touched by the weather and battery modules, and stays meaningful across restarts.

The old Modbus path is still there behind automation.discharge.fallback-to-manual-mode, off by default.


Modules

Every automation is an independent module: its own package, its own configuration section, its own widget on the dashboard, and its own enabled flag. Nothing enumerates them by name — dropping a new AutomationModule bean on the classpath is enough for the registry, the dashboard and the timeline to pick it up. Deleting a module means deleting its package.

Module Config prefix What it does
Battery charge guard automation.battery Checks the battery against charge targets through the day: switches to self use when behind schedule, and to feed-in priority when comfortably ahead of it so surplus production is sold rather than wasted.
Export limit automation.export Closes the export limit while the spot price is too low to be worth selling, and throttles it around midday on dull days. Runs every quarter of an hour, matching how often the price changes.
Weather work mode automation.weather Chooses between feed-in priority and self use from the forecast, and moves to backup ahead of a thunderstorm.
Grid selling automation.discharge Finds the most valuable quarter-hour window of the day and sells the battery into it through remote control.

Writing a new module

@Component
public class MyModule extends AbstractAutomationModule<MyProperties> {

    public MyModule(MyProperties properties) {
        super(properties);
    }

    @Override public String getId()           { return "my-module"; }
    @Override public String getName()         { return "My module"; }
    @Override public String getDescription()  { return "One or two sentences."; }
    @Override public String getConfigPrefix() { return "automation.my-module"; }

    @Override
    public List<ConfigEntry> getConfiguration() {
        return List.of(ConfigEntry.of("automation.my-module.threshold", "Threshold",
                properties.getThreshold(), "%", "What this value controls"));
    }

    @Scheduled(cron = "0 7 * * * *")
    public void check() {
        run("Hourly check", () -> {
            // ... read state, decide, act
            return RunOutcome.unchanged("Nothing to do");
        });
    }
}

MyProperties implements ModuleProperties and is a plain @ConfigurationProperties class. The base class handles the enabled check, the run header, timing, failure capture and the dashboard status.


Selling: how the window is chosen

The Czech market settles in 15 minute intervals, so a day has 96 prices rather than 24 — the application uses /api/v1/price/get-prices-json-qh throughout (the hourly get-prices-json endpoint is deprecated).

Selling only into the single most expensive interval wastes most of the battery; selling across the whole evening gives energy away at mediocre prices. DischargeWindowPlanner therefore works in three steps:

  1. Peak — the most expensive interval inside search-fromsearch-to.
  2. Plateau — grow outwards from the peak while neighbouring intervals stay within price-tolerance (1 CZK/kWh by default) of it. That run is the part of the evening genuinely worth selling into.
  3. Fit — the battery rarely covers the whole plateau, so slide a window of the length the battery can actually sustain ((soc − reserve) × capacity × efficiency ÷ discharge-power) across the plateau and keep the placement that earns the most. Equal-earning placements resolve to the latest one, which pushes the discharge towards the end of the plateau instead of starting at its first interval and running dry before the peak.

Planning never looks at the battery. It runs at 15:00, hours before the evening peak, with the sun still charging — the level read then says nothing about the level at 19:00. So a window is armed on price alone, and soc in the formula above is min-battery (50 % by default: the charge the sale requires anyway), floored at whatever the battery already has. Whether the sale is actually worth starting is decided again when the window opens, against that same min-battery: too little charge and the window is simply dropped, with the reason in the log. A window armed by hand from the dashboard skips that check — it is the person's call — but never the reserve.

Over-estimating is safe either way: the guard ends the sale as soon as the reserve is reached. Under-estimating is not, because it arms a window too short to use the peak.

discharge-power is not configured separately — it is automation.export.power.maximum, since a sale can never leave the installation faster than that ceiling allows anyway.

At the window's start a remote control session is opened for exactly the window's length. A guard checks the battery every guard-interval and ends the session early once the reserve is reached. If the export limit happens to be closed at that moment, the run logs a warning rather than quietly trickling energy out at the limit.

The placement rules are covered by DischargeWindowPlannerTest — they decide how much money the battery earns, so they are pinned down rather than only observed in production logs.


Dashboard

http://<host>:8080/ — no build step, no CDN, works offline on the Pi.

Overview — live battery/PV/grid/load, work mode, current price, and the Raspberry Pi's connection switch (HIGH is the metered grid, LOW the second supply — the tile says which, and says plainly when it is the off-Pi stub rather than a pin); the day's 96 quarter-hour prices with the armed selling window highlighted; the weather quality curve with the thresholds the modules compare against; a 24 hour timeline of what every module intends to do; and recent activity.

The timeline shows every run each module has coming up, not just the next one. Two modules are left out of it: the export limit is re-checked every quarter of an hour and the weather work mode every hour, nearly always with the same outcome, and 92 identical rows bury the handful that say something. Their own widget on the modules page always shows the full schedule.

The list beneath the chart pages in tens, so a long plan stays one screen tall. The page you are on survives a refresh.

Recent activity survives a restart: the newest timeline.persisted-events entries are kept in a small JSON file (data/timeline.json by default). It is a convenience for the dashboard, not an audit log - the rolling log files remain the durable record.

All three charts are hoverable. A price interval reports its exact price in both currencies and how it compares with that day's average; a forecast hour reports its quality, the band that quality falls into, cloud cover and temperature; a planned action reports the module behind it, its kind, the window, how long it lasts, how far away it is and whether it is committed or a routine check. The weather quality formula sits behind the ⓘ button in that card's header rather than taking up space on every visit, and the two thresholds are named in the legend instead of being written across the plot.

Modules — two columns of widgets, each split into three panels: status (what the module is and how its last run went), configuration (every documented value it reads) and plan (what it will do next). A switch disables a module until the next restart. Every card is exactly as tall as its own content: the page lays them out in columns rather than grid rows, so a module with fifteen configuration values does not set the height of a row and leave the card beside it half empty, and nothing is clipped or scrolled. The status line appears once the module has something to report — a module that has not run yet says nothing rather than "Idle · not run yet", and a module mid-run says what it is doing rather than leaving the previous line up.

The page re-fetches every dashboard.refresh-seconds (a minute by default, which is about as fast as the underlying values actually move), and shows skeleton placeholders until the first fetch lands.

Why it is fast. Reading the inverter is slow: every Modbus request is spaced a second apart by the request queue, so one snapshot costs several seconds and can queue behind a module's own reads. Blocking the browser on that made every poll feel like a hang. The gateway therefore serves the last reading and refreshes behind it, and warms the cache at start-up, so no request ever waits on Modbus - a full dashboard load is a few hundred milliseconds. The values are at most one refresh interval old, well inside how fast any of them move.

Selling controls — the card carries the decisions and arming happens in a dialog. With nothing armed there is Arm; with a window armed there is Disarm and Re-arm, which opens the dialog pre-filled with the current window. Re-plan now re-runs the planner either way.

The dialog arms in two shapes: between two times, or starting now for a chosen duration. "Start now" is anchored to the application's clock rather than the browser's, so a browser whose clock is off cannot arm a window that begins in the past. Either way it previews the window, its length and roughly how much energy it will move before anything is armed.

Quick actions — the card beside selling, for what the automation cannot know about: a car to charge tonight, a storm the forecast missed, a sale to stop early. It is split the way the commands themselves are:

  • Work modeSelf use, Feed-in priority, Backup. Persistent: it survives a restart, and a module may well move it again at its next run. The mode the inverter is already in is marked.
  • Remote controlCharge from grid, Sell to grid (the same dialog the selling card opens) and Exit remote control. These hand the inverter back on their own, even if this application stops; the work mode is left alone. They need the SolaX Cloud connection, and say so plainly when it is not configured.

Charging takes either shape: for a time, or to a battery level. Fill in To SOC and the session runs until the battery gets there, however long that takes — that is the cloud's soc_target_control_mode, which carries no timer and which the inverter itself ends when the target is met. The duration dims to show it is not being used, and the line under the fields spells out which of the two will happen before anything is sent.

Exiting remote control while a sale is running cancels it through the selling module rather than behind its back, so the armed window and the history stay in step with the inverter.

Leaving remote control takes two commands, not one. exit_vpp_mode is reported successful the moment the cloud has queued it, and some inverters stop the session but stay in their remote-control running state — Normal Mode(R-n) in the SolaX app — until the documented exit remote control transition actually runs. So the exit is sent as a one second, zero power session with nextMotion = 160 first, and the direct exit lands on top of it. One second at 0 W changes nothing about the battery. Set solax.cloud.exit-with-push-power: false if your inverter leaves on the direct exit alone.

English and Czech, light/dark/system theme, both remembered per browser. Module names, descriptions, configuration labels, planned actions, history entries and lifecycle statuses are translated; per-run outcome sentences stay in English on purpose, because they are the same wording the log file contains.

Set dashboard.allow-control: false if the dashboard is reachable from outside your local network — the application has no authentication of its own.


Logs

Appenders live in src/main/resources/log4j2.xml. Despite the name that file is logback configuration and always has been - logback is the backend Spring Boot brings in by default.

Every module run reads as a short report rather than a stream of unrelated lines:

══════════════════════════════════════════════════════════════════════════════
[discharge] Evaluating today's prices for a selling window
──────────────────────────────────────────────────────────────────────────────
[discharge]   · Battery .................. 87 % now, planning for 100 % (need 50 % to sell, reserve 40 %)
[discharge]   · Search window ............ 15:00 - 23:45 (36 intervals)
[discharge]   · Peak ..................... 19:15 at 8.85 CZK/kWh
[discharge]   · Peak plateau ............. 18:30-20:30 (120 min within 1.0 CZK/kWh)
[discharge]   · Usable energy ............ 6.4 kWh -> 6 interval(s) at 3950 W
[discharge]   · Selling into
[discharge]       | 19:15-19:30   8.85 CZK/kWh  (high, rank 96/96)
[discharge]       | 19:30-19:45   8.79 CZK/kWh  (high, rank 95/96)
[discharge]       | 19:45-20:00   8.61 CZK/kWh  (high, rank 93/96)
[discharge]       | 20:00-20:15   8.40 CZK/kWh  (high, rank 91/96)
[discharge]   ✓ Armed 19:15 - 20:45 at 3950 W (starts in 3 h 42 min)

Every line carries its module id, so one module can be grepped out of a shared file even when runs interleave. Console output is coloured; logs/app.log rotates daily and is kept for 30 days.


Prerequisites

Hardware — Raspberry Pi 4B, a Solax X3-Hybrid-G4 with Modbus TCP reachable (an RS485→Ethernet converter in front of it is fine), optionally a GPIO switch on BCM 17 reporting which supply the house is on.

Accounts

  1. Meteosource — free tier is enough.
  2. SolaX developer portal — create an application, note the client id/secret, your account's API URL, and the inverter serial number. Required for selling.
  3. spotovaelektrina.cz — no key needed.

Software — Java 21, Maven 3.x, and network access from the Pi to the inverter.


Install

git clone https://github.com/Firestone82/SolaxAutomation.git
cd SolaxAutomation
./mvnw clean package
java -jar target/SolaxAutomation-*.jar

Configuration lives in src/main/resources/application.yml, which documents every value. Keep secrets out of it — anything can be overridden from the environment:

export SOLAX_CLOUD_CLIENT_ID=...
export SOLAX_CLOUD_CLIENT_SECRET=...
export METEOSOURCE_KEY=...

As a service:

[Unit]
Description=Solax Automation
After=network-online.target
Wants=network-online.target

[Service]
User=pi
WorkingDirectory=/home/pi/SolaxAutomation
ExecStart=/usr/bin/java -jar /home/pi/SolaxAutomation/target/SolaxAutomation-0.0.1-SNAPSHOT.jar
EnvironmentFile=/home/pi/SolaxAutomation/.env
Restart=on-failure
RestartSec=30

[Install]
WantedBy=multi-user.target
sudo systemctl daemon-reload
sudo systemctl enable --now solax-automation

Running away from the installation

java -jar target/SolaxAutomation-*.jar --solax.modbus.enabled=false --raspberry.enabled=false

Modbus and the GPIO switch are stubbed out, the dashboard still serves real prices and weather.


Safety limits

These exist because the far end is real hardware, and they stop the application rather than let a bug run away with it:

  • Write budget — at most solax.modbus.max-writes-per-window writes per write-window (10 per 12 h by default). Exceeding it shuts the application down.
  • Failure limitmax-consecutive-failures consecutive Modbus errors shut it down.
  • Request spacing — all Modbus requests are serialised onto one thread and spaced by request-delay; the inverter drops requests that arrive faster.
  • Connection recycling — the inverter closes idle connections itself, so a connection idle longer than idle-timeout (30 s) is re-opened deliberately, and any request that still hits a closed socket is retried once on a fresh connection. Reconnecting costs about 20 ms.
  • Fail fast — an inverter that cannot be reached at start-up stops the application, so a supervisor restarts it. Set solax.modbus.fail-fast: false to keep the dashboard up instead.

Project layout

core/            module federation: AutomationModule, registry, timeline, logging
integration/
  solax/         InverterGateway + modbus/ (registers, queue, client) + cloud/ (OpenAPI)
  ote/           quarter-hour spot prices
  meteosource/   weather forecast
  raspberry/     GPIO supply switch
module/
  battery/ export/ weather/ discharge/     one package per automation
dashboard/       REST API + DTOs; the SPA lives in resources/static

License & disclaimer

Provided "as-is" for personal use. No warranty. Adapt it for your needs, but please do not redistribute without permission.

About

Raspberry Pi automation for a Solax X3-Hybrid inverter using weather forecasts and spot electricity prices