drivers: regulator: read current level from the device
Always read current voltage level from the device instead of caching the level in struct regulator. This fixes issues for when the regulator level value depends on the parent regulator (supply). It is up the regulator driver to cache or not this value in their private data if applicable. Fixes: 1a3d327 ("drivers: regulator framework") Signed-off-by: Patrick Delaunay <patrick.delaunay@foss.st.com> Change-Id: Ic880c41c9a2c30f7730808ea1398a13d99be234b