Device Specific Information

Supports ClearOne CONVERGE Pro 2 evices

Communication Settings

Setting Value
Delimiter "\n"
Default Baud 57600
Data Bits 8
Stop Bits 1
Parity none
Flow Control none
Telnet Port 23

Valid communication methods

com
tcpIp

Configuration Objects

Type: convergepro2dsp

Device Configuration

{
	"key": "dsp1",
	"name": "ClearOne Converge Pro 2",
	"type": "convergePro2",
	"group": "plugin",
	"properties": {
		"control": {
			"method": "tcpip",
			"controlPortDevKey": "processor",
			"controlPortNumber": 1,
			"comParams": {
				"protocol": "RS232",
				"baudRate": 57600,
				"dataBits": 8,
				"stopBits": 1,
				"parity": "None",
				"hardwareHandshake": "None",
				"softwareHandshake": "None"
			},
			"tcpSshProperties": {
				"address": "10.0.0.194",
				"port": 23,
				"username": "admin",
				"password": "password",
				"autoReconnect": true,
				"autoReconnectIntervalMs": 10000
			}
		},
		"communicationMonitorProperties": {
			"pollInterval": 60000,
			"timeToWarning": 180000,
			"timeToError": 300000
		},
		"boxName": "DSP1"
	}
}

Level Control Blocks Configuration

Block Number (BN) - Configuration property blockName

Refers to the end point block corresponding to some functionality of the endpoint, for level control blocks the most commonly used value is:

  • "blockName": "LEVEL"

Paraemeter Name (PN) - Configuration properties levelParameter & muteParameter

Parameter names will vary based on the Block Numbers (BN) used to configure the blockName property. The most commonly used values are:

  • "levelParameter": "GAIN"
  • "muteParameter": "MUTE"
{
	"properties": {
		"levelControlBlocks": {
			"fader-main": {
				"label": "Main",
				"channelName": "SPKR_ZN_1",
				"blockName": "LEVEL",
				"levelParameter": "GAIN",
				"muteParameter": "MUTE",
				"disabled": false,
				"hasLevel": true,
				"hasMute": true,
				"isMic": false,
				"useAbsoluteValue": false,
				"unmuteOnVolChange": true
			}
		}
	}
}

Presets Configuration

{
	"properties": {
		"presets": {
			"preset1": {
				"label": "System On",
				"preset": "1"
			},
			"preset2": {
				"label": "System Off",
				"preset": "2"
			},
			"preset3": {
				"label": "Default Levels",
				"preset": "3"
			}
		}
	}
}

"preset" is the name of the macro to run, the name is case sensitive.

Dialer COntrol Blocks Configuration

{
	"properties": {
		"dialers": { 
			"dialer1": {
				"label": "Dialer", 
				"channelName": "VOIP1",
				"isVoip": true, 
				"clearOnHangup": true
			}			
		}
	}
}

isVoip will change the command sent to include the endpointType UA.

i.e. EP UA {channelName} KEY KEY_CALL {dialString}

Bridge Configuration

Appliance

{
	"key": "dsp1-bridge",
	"name": "DSP Bridge",
	"group": "api",
	"type": "eiscApiAdvanced",
	"properties": {
		"control": {
			"method": "ipidTcp",
			"tcpSshProperties": {
				"address": "127.0.0.2",
				"port": 0
			},
			"ipid": "a2"
		},
		"devices": [
			{
				"deviceKey": "dsp1",
				"joinStart": 1
			}
		]
	}
}

Server (VC-4)

{
	"key": "dsp1-bridge",
	"name": "DSP Bridge",
	"group": "api",
	"type": "vcEiscApiAdvanced",
	"properties": {
		"control": {
			"ipid": "d1",
			"method": "ipid",
			"roomId": "ROOM01SIMPL"
		},
		"devices": [ 
			{ 
				"deviceKey": "dsp-dialer1", 
				"joinStart": 1 
			} 
		]
	}
}

SiMPL EISC Bridge Map

The selection below documents the digital, analog, and serial joins used by the SiMPL EISC. Update the bridge join maps as needed for the plugin being developed.

ConvergePro2DspJoinMap

Digitals

Join Number Join Span Description Type Capabilities
1 1 Is Online Digital FromSIMPL
101 100 Preset Recall Digital FromSIMPL
201 200 ControlTag Visible Digital FromSIMPL
401 200 ControlTag Mute Toggle Digital ToFromSIMPL
601 200 ControlTag Mute On Digital ToSIMPL
801 200 ControlTag Mute Off Digital ToSIMPL
1001 200 ControlTag Volume Up Digital FromSIMPL
1201 200 ControlTag Volume Down Digital FromSIMPL
3100 1 Call Incoming Digital ToSIMPL
3106 1 Answer Incoming Call Digital FromSIMPL
3107 1 End Call Digital FromSIMPL
3110 10 Keypad Digits 0-9 Digital FromSIMPL
3120 1 Keypad * Digital FromSIMPL
3121 1 Keypad # Digital FromSIMPL
3122 1 Keypad Clear Digital FromSIMPL
3123 1 Keypad Backspace Digital FromSIMPL
3124 1 Keypad Dial and Feedback Digital ToFromSIMPL
3125 1 Auto Answer On and Feedback Digital ToFromSIMPL
3126 1 Auto Answer Off and Feedback Digital ToFromSIMPL
3127 1 Auto Answer Toggle and On Feedback Digital ToFromSIMPL
3129 1 On Hook Set and Feedback Digital ToFromSIMPL
3130 1 Off Hook Set and Feedback Digital ToFromSIMPL
3132 1 Do Not Disturb Toggle and Feedback Digital ToFromSIMPL
3133 1 Do Not Disturb On Set and Feedback Digital ToFromSIMPL
3134 1 Do Not Disturb Of Set and Feedback Digital ToFromSIMPL

Analogs

Join Number Join Span Description Type Capabilities
1 1 Device communication monitor status feedback Analog ToSIMPL
2 1 Device socket status feedback Analog ToSIMPL
201 200 ControlTag Volume Analog ToFromSIMPL
401 200 ControlTag Type Analog ToSIMPL
3100 1 Call State Feedback Analog ToSIMPL

Serials

Join Number Join Span Description Type Capabilities
1 1 Device Name Serial ToSIMPL
101 100 Preset Name Serial ToSIMPL
201 200 Channel Name Serial ToSIMPL
3100 1 Dial String Send and Feedback Serial ToFromSIMPL
3101 1 Dialer Label Serial ToSIMPL
3102 1 Last Number Dialed Feedback Serial ToSIMPL
3104 1 Caller ID Number Serial ToSIMPL
3105 1 Caller ID Name Serial ToSIMPL
3106 1 This Line's Number Serial ToSIMPL

DEVJSON Commands

devjson:1 {"deviceKey":"dsp1", "methodName":"SetDebugLevels", "params":[2]}
devjson:1 {"deviceKey":"dsp1", "methodName":"ResetDebugLevels", "params":[]}